Measure the resistance between terminal
pins of connector KEY CONNECTOR.
NOTE:
When reconnecting the FPC connector,
make sure that the holes on the FPC
connector are properly engaged with hooks
on the plastic fastener.
MATRIX CIRCUIT FOR
TOUCH KEY BOARD
CONNECTOR(KEY CON)
7-17
COMPONENTS TEST PROCEDURES RESULTS
TOUCH KEY
BOARD
SENSOR
Resistance
value
When When not
touched touched
Less than More than
400 ohms 1 mega ohm
FPC CONNECTOR
Top
Normal: Approximately
BK-RD: 5.6 Kohms
RD-WH: 2.8 Kohms
BK-WH: 2.8 Kohms
Abnormal:
Infinite or several
*Sensor cooking condition
1. Oven should be plugged in at least 5
minutes before sensor cooking.
2. Room temperature should not exceed
95˚F.
3. Be sure the exterior of the cooking
container and the interior of the oven
are dry.
4. The oven will not generate microwave
energy for the first 28 seconds of the
sensor cooking cycle.
Figure 28
Figure 27
1. Disconnect sensor connector from micom
computer board.
2. Measure resistance terminal to terminal
(Select the ohm scale on the meter)
NOTE: MAKE SURE THE LEAD WIRES ARE
IN THE CORRECT POSITION.
WHEN REMOVING THE LEAD
WIRES FROM THE PARTS, BE
SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Figure 29