OPERATION AND ADJUSTMENT
APPLYING SILICONE LUBRICANT
To reduce the fdction of the walking belt and minimize
wear, a non-oil-, non-petroleum-base silicone lubri-
cant must be applied to the walking platform before
the treadmill is used. Failure to apply lubricantwill
reduce treadmill performance. WITH THE POWER
CORD UNPLUGGED, lift each side of the walking belt
and spray lubricant generously onto the indicated
area. Reapply lubricant after every ten hours of use,
or whenever performance decreases. Lubricant is
available at most hardware and automotive stores.
Uni.SportTM silicone spray is recommended.
Apply lubricant to the
entire shaded area.
and has a grounding PlUg that looks like the p!ugillus-
trated in Drawing 1.
A temporary adapter that looks like the adapter illus-
trated in Drawing 2 may be used to connect this plug
to a 2-pole receptacle as shown in Drawing 2 if a
properly grounded outlet is not available. The tempo-
rary adapter should be used only until a properly
grounded outlet (Drawing 1) can be installed by a
qualified electrician. The green colored .rigidear, lug,
or the like extending from the adapter must be con-
nected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter is
used it must be held in place by a metal screw.
Some 2-pole receptacle outlet box covers are not
grounded. Contact a qualified electrician to deter-
mine if the outlet box cover Is grounded before
using an adapter.
Grounded
Box
Silicone Lubricant
PLUGGING IN THE POWER CORD
This product must be grounded. If it should mal-
function or break down, grounding provides a path of
least resistance for electric current to reduce the risk
of electric shock.
This product is equipped with a cord having an equip-
ment-grounding conductor and a grounding plug.
Plug the power cord Into an appropriate outlet
that is properly Installed and grounded in accor-
dance with all local codes and ordinances.
DANGER: Improper connection of the
equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or
serviceman if you are In doubt as to whether the prod-
uct is properly grounded. Do not modify the plug pro-
vided with the product--if it will not fit the outlet, have
a proper outlet installed by a qualified electrician.
This product is for use on a nominal 120-volt cimuit,