7. TEST MODE
21
7-1. SAFETY CAUTION
There's built-in AC 110V and DC power in output terminal of PWB assembly in common. Be careful electric
shock when disconnecting parts while trouble shooting. (Wear Electro Static Discharge gloves when working.)
After cutting off the power when changing PWB assembly, disconnect or assemble.
Be careful static when handling PWB assembly, and use Electro Static Discharge plastic pack when delivering
or keeping it.
7-2. LOAD TEST MODE.
The washer must be empty and the controls must be in the off state.
1. Press the SPIN SPEED and SOIL LEVEL buttons simultaneously.
2. Press the POWER button, while the above condition. Then buzzer will sound twice.
3. Press the START/PAUSE button repeatedly to cycle through the test modes.
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
Press the WASH/RINSE and DELAY S button simultaneously.
The digits indicate the water level frequency ( x.1 kHz ).
So, for example a display indicating 241: a Water level frequency of 241 x.1 kHz
= 24.1 kHz
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
11 times
Turns on all lamps and locks the door.
Tumble clockwise.
Low speed Spin.
High speed Spin.
It will be take about 2minits to be
high speed spin
Inlet valve for prewash turns on.
Inlet valve for main wash turns on.
Inlet valve for hot water turns on.
Inlet valve for bleach turns on.
Tumble counterclockwise.
Heater turns on for 3 seconds.
Drain pump turns on.
off
LOAD TEST MODE
rpm (42~50)
rpm (35~45)
rpm (110~117)
Water level frequency (0~255)
Water level frequency (0~255)
Water level frequency (0~255)
Water level frequency (0~255)
rpm (42~50)
Water temperature
Water level (0-255)
-
Number of times the
Start/Pause button is pressed
Check Point
Display Status
NOTES:
RPM < 220 : RPM = display / RPM > 200 : RPM = display X 10
WATER LEVEL : o255 = empty / o248 = normal / o255 = tub clean